Home » Products » CPM Particulate Monitors » CPM 5003 Model

 

Accurate Particulate Detection

Why use it?
Comparison
Which one do I need?
CPM 700 series
CPM 5001 series
CPM 5003 series
FAQ's
 

CPM® 5003 Features:

  • No drift, self-compensating technology
  • Designed and built to IPC-A-610B, class 3 specifications for high performance electronics
  • High intensity divergent LED (standard) or laser (optional) light source
  • Full cross-duct sampling
  • Ambient light detection and compensation
  • Maintenance alarm
  • Isolated analog output
  • Single- or Multi-Point Capability*
  • Dual-stage emissions alarms
  • RS 232 local or remote communications
  • Remote diagnostic capability
  • Automatic zero and span calibration
  • High speed - programmable dual microprocessor
  • 30 day on-board data storage
  • Multiple calibration and correlation
  • Dedicated purge air blower
  • Automatic calibration selection switch
  • On-board help screens


 
The CPM 5003 has been designed to comply with the US EPA requirements for the fulfilment of Performance Spec 11.
 

The Best, Most Reliable Particulate Monitor in the World

The CPM 5003 is BHA’s most advanced particulate emissions monitoring system. It is designed to provide years of trouble-free service with minimal maintenance. The CPM 5003 provides superior monitoring with many new powerful features. Certain applications require multiple calibration capability. The CPM 5003 can automatically switch between calibrations based on changing operating conditions or scenarios. The CPM 5003 also offers multiple calibration configurations for applications where a simple linear correlation is not sufficient.

CPM 5003 particulate monitors use a pair of sensors mounted to flanges that are attached to the point you want to monitor. Insulators are installed between the mounting flange and the sensors to allow for high gas stream temperatures.

The CPM 5003 system includes a dual microprocessor control unit, transmitter, and receiver. A modulated LED light source standard. The CPM 5003 is designed so that up to 255 monitoring points can be connected to the operator interface, an industrial hardened computer. Through the operator interface station, the operator can monitor and control all the CPM 5000 Series monitors in the system using BHA’s System Monitoring Software. The distance between monitoring points can be up to 2 miles (3.2 km).

The CPM microprocessor has been designed with built-in memory so if communications are lost between the operator interface and the controller, the continuous data can be saved in the microprocessor for 30 days. This assures that no data is lost while communications are being re-established. This data can then be downloaded through the operator interface station (remotely) or by connecting a laptop PC to each controller so the information can be downloaded in the field (locally).

The CPM 5003 includes a dedicated purge air blower that provides an adequate supply of clean, dry purge air.

* Multi-Point capability requires use of PC and WinCPM™ software.


Technical Specifications

LED Transmitter Head
Material: Acetal
Power Input: +15 VDC from the microprocessor controller
Flange Dimensions: 2.5" 150# ASA flange
Air Purge Connection: 1/4" NPT (6.35 mm)
Purge Air Requirements: 5 psi above duct pressure
Purge Air Diffuser: replaceable cartridge
Process Temperature Range: -12°C to 343°C
Ambient Temperature Range: -12°C to 57°C
Weight: 1.3 kg
Light Source: Light Emitting Diode (LED)


Receiver Head
Material: Acetal
Power Input: +15 VDC from the microprocessor controller
Flange Dimensions: 2.5"150# ASA flange
Air Purge Connection: 1/4" (6.35 mm)
Purge Air Requirements: 5 psi above duct pressure
Purge Air Diffuser: Replaceable cartridge
Process Temperature Range: -12°C to 343°C
Ambient Temperature Range: -12°C to 57°C
Weight: 1.5 kg


Microprocessor Controller
Measuring Range: 0.1-3,000 mg/m?
Enclosure Material: Steel
Protection: NEMA Type 4, 12
Power Input: 100-240 VAC, 50/60 Hz
Temperature Range: -18°C to 50°C
Temperature Protection: Thermostatically Controlled Survival Heater
Software Alarms: Five
Hardware Alarm Relays (Optional): Four
Relay Type: SPST, Normally Open
Relay Maximum Switched Current: .5 amps @ 130 VAC
Relay Maximum Switched Voltage 130 VAC, 100 VDC
Analog Output (Optional): One, 4 - 20 mA
Display (Optional): Back-Lit LCD
Keypad (Optional): Environmentally Sealed, Tactile Feedback
Local Communications Port: RS-232 Compatible
Remote Communications Port: 0 - 20 mA Isolated Serial
Communications Protocol: 9600 Baud, 7 Bit, Odd Parity, One Stop Bit
Weight: 13.4 kg
Dimensions: 406 x 305 x 175 mm
« Previous | Next »


Home | Products and Services | Electrostatic Precipitators | Bagfilters | News and Events | About Us | BHA Website
Site last updated 29th April 2005

©2005 Total Air Pollution Control Pty Ltd.
All Rights Reserved. Unauthorised copying and reuse of any content in any form is strictly prohibited.
Use of this Web site constitutes acceptance of the TAPC User Agreement and Privacy Policy.