Accurate Particulate Detection

Why use it?
Comparison
Which one do I need?
CPM 700 series
CPM 5001 series
CPM 5003 series
FAQ's
 

CPM® 700 Series Particulate Detector

CPM 700 Series monitors are advanced detection devices that measure changes in particulate concentration. Using a unique emissions detection technique, CPM 700 Series instruments maintain calibration because they remain virtually unaffected by dirty or misaligned optics, or an aging light source.

The CPM 700 Series Particulate Detection System provides advanced broken bag detection and prediction as well as monitoring of changes in particulate concentration. This product line features two models, the CPM 700 and the CPM 750.

The CPM 700 model serves primarily as a broken bag detector. An alarm is activated when a pre-set particulate emissions level is exceeded. The CPM 750 model includes a 4-20 mA analog output module.

CPM 700 Series Instruments Include:

  • Self-compensating emissions detection technique; no drift and low maintenance.
  • Instant notification of high emissions or unfavorable conditions with Emission Alarm and Maintenance Alarms.
  • Automatically detects and adjusts for ambient light.
  • Adjustment to process characteristics.
  • Precise and easy to read analog meter.
  • Adjustable damping to allow for smooth response to rapid fluctuations in emissions.

CPM® 750 Features

CPM 750 includes features for the CPM 700 as well as a 4-20 mA analog output module that allows the connection to a strip chart recorder, DCS system, or BHA's InPoint® Manager, which allows remote monitoring and trending of dust levels, or a CPM 5000 multi-point system, which allows the user to monitor the emissions level from a remote location.

Installation

The graphic above shows the simple installation
of this system at the emissions point.

Technical Specifications

Transmitter Head
Material: 6061 Aluminum
Protection: NEMA-4x
Power Input: ± 15 VDC from the CPM 700/750
Receiver Head Air Purge Connection: 1/4 in. (6.35 mm)
Purge Air Requirements: Minimum 5 psi Above Duct Pressure
Temperature Range:

Process:
Ambient:

-12° C to 177° C
-12° C to 57° C

Weight: 3.0 kg
Light Source: Light Emitting Diode (LED)

 
Receiver Head/Electronics
Material: Steel
Protection: NEMA Type 4, 12
Power Input: 100-240 VAC, 50/60 Hz
Air Purge Connection: 1/4 in. (6.35 mm)
Purge Air Requirements: Minimum 5 psi Above Duct Pressure
Temperature Range:

Process:
Ambient:

-12° C to 177° C
-12° C to 57° C

Hardware Alarm Relays: Two
Relay Type: Solid State Relay
Operating Voltage Range: 24-280 VAC 25-65 Hz
Relay Current Rating: 3A at 45° C ambient
Relay Off State Leakage: 2.5 mA RMS at 120 VAC
Analog Output: One; 4-20 mA
Dimensions: 203 x 254 x 102 mm
Weight: 5.4 kg
Minimum Duct Width: 75 mm
Maximum Duct Width: 6 m
Supplied Interconnecting Cable: 15 m
« Previous | Next »


Home | Products and Services | Electrostatic Precipitators | Bagfilters | News and Events | About Us | BHA Website
Site last updated 29th April 2005

©2005 Total Air Pollution Control Pty Ltd.
All Rights Reserved. Unauthorised copying and reuse of any content in any form is strictly prohibited.
Use of this Web site constitutes acceptance of the TAPC User Agreement and Privacy Policy.