Case History #1: Chemical Production Facility
| Facility/Location: |
Chemical production in Wyoming |
| Equipment: |
3-field ESP off a soda ash calciner |
| Installation Data: |
All three fields have been fitted with JuiceCans®. |
| Performance Data: |
The opacity has dropped from the high teens to single digits. The unit
was stack tested recently and actually tested better than when it was brand new. |
| Customer comments: |
"These are the best investment we have
ever made on our precips." |
Case History #2: Power Industry
| Facility/Location: |
Large power plant in the Midwest |
| Equipment: |
5-field ESP off a coal-fired boiler |
| Installation Data: |
Three JuiceCans® are currently installed on the inlet second and
middle fields. |
| Performance Data: |
This customer was skeptical of results that we showed him, and ran his
own study over a six-month period doing a band statistical analysis. |
| Customer comments: |
He determined that the opacity had been reduced by 22%, and the only
thing that he could attribute it to was the JuiceCan®. |
Case History #3: WTE Facility
| Facility/Location: |
Waste Incinerator Facility in Virginia |
| Equipment: |
2-field ESP |
| Installation Data: |
A Juice Can® was installed during the development phases, and there
was an immediate reduction in opacity. The plant manager told BHA engineers: |
| Customer comments: |
"I don't know what you are doing, but keep
doing it." |
Case History #4: Power Industry
| Facility/Location: |
A California power producer |
| Equipment: |
3-field precipitator off a multifuel boiler. A mix of refuse and grape
vines, nut shells, and other matter is used as fuel. |
| Installation Data: |
A single JuiceCan® was installed in the inlet field. |
| Performance Data: |
Secondary voltage increased by 53%, the opacity dropped, and they immediately
saw increases in the voltage of the 2nd and 3rd fields due to the inlet collecting more of
the dust. |
Case History #5: Paper Industry
| Facility/Location: |
Paper Mill in Spain
|
| Equipment: |
2-field precipitator off a Recovery boiler. |
| Installation Data: |
JuiceCans® were installed on both fields. |
| Performance Data: |
Secondary Power levels increased. Opacity decreased 25% |
Case History #6: Power Industry
| Facility/Location: |
Power plant in the mid-west |
| Equipment: |
Inlet field of a 4 field ESP power boiler where field 1D is actually
the inlet field and field 1A is the outlet field |
| Installation Data: |
A single JuiceCan® was installed in the inlet field. |
| Performance Data: |
Secondary Voltage increased from 26.5 to 42.1 kV on field 1C.
Secondary Voltage actually decreased slightly from 45.0 kv to 40.8 kv on field 1B. (There
may be a possible mechanical problem within this field)
Secondary Voltage increased from 25.0 to 40.9 kV on field 1A
|
|